View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000994 | CaseTalk Modeler | Diagrams | public | 2016-06-06 14:11 | 2022-01-10 20:32 |
Reporter | BCP Software | Assigned To | BCP Software | ||
Priority | normal | Severity | major | Reproducibility | sometimes |
Status | closed | Resolution | fixed | ||
Product Version | 8.9.1 | ||||
Target Version | 9.0 | Fixed in Version | 8.10.1 | ||
Summary | 0000994: Syncing shows issue where duplicate OTFT may occur | ||||
Description | Diagrams which are a long time out of sync during model edits, may show duplicate OTFT's in diagram after synchronization. | ||||
Tags | No tags attached. | ||||
CaseTalk Edition | |||||
related to | 0000975 | closed | BCP Software | After IG and IGD checkout, the IGD shows wrong result |
When duplicates occur, at least one of the OTFT's is no longer updated with the current state of the model. | |
Closing automatically, stayed too long in resolved state. Feel free to re-open with additional information if you think the issue is not resolved. | |
Date Modified | Username | Field | Change |
---|---|---|---|
2016-06-06 14:11 | BCP Software | New Issue | |
2016-06-06 14:11 | BCP Software | Status | new => assigned |
2016-06-06 14:11 | BCP Software | Assigned To | => BCP Software |
2016-06-06 14:11 | BCP Software | Note Added: 0000599 | |
2016-06-06 14:12 | BCP Software | Status | assigned => resolved |
2016-06-06 14:12 | BCP Software | Fixed in Version | => 9.0 |
2016-06-06 14:12 | BCP Software | Resolution | open => fixed |
2016-06-06 14:12 | BCP Software | Relationship added | related to 0000975 |
2016-06-06 21:20 | BCP Software | Fixed in Version | 9.0 => 8.10.1 |
2022-01-10 20:32 | BCP Software | Note Added: 0002216 | |
2022-01-10 20:32 | BCP Software | Status | resolved => closed |