View Issue Details

IDProjectCategoryView StatusLast Update
0000602CaseTalk ModelerImport and Exportpublic2022-01-10 20:40
ReporterBCP Software Assigned ToBCP Software  
PrioritynormalSeverityminorReproducibilitysometimes
Status closedResolutionfixed 
Product Version8.1.2 
Fixed in Version8.1.3 
Summary0000602: Diagram viewer when a IGG is active fails
DescriptionWhen a IG is transformed into a IGG, the menu option "Diagram/Open in Viewer" will start the CaseTalk Viewer with an error mentioning the IGGX file is not found.

And indeed this file does not seem to exist.
TagsNo tags attached.
CaseTalk Edition

Activities

BCP Software

BCP Software

2015-02-09 17:09

administrator   ~0000338

The creation of ig(g)x files is required for the Viewer. They are now saved upon project and ig saving in all editions of CaseTalk.
BCP Software

BCP Software

2022-01-10 20:40

administrator   ~0002680

Closing automatically, stayed too long in resolved state. Feel free to re-open with additional information if you think the issue is not resolved.

Issue History

Date Modified Username Field Change
2015-02-09 16:02 BCP Software New Issue
2015-02-09 16:02 BCP Software Status new => assigned
2015-02-09 16:02 BCP Software Assigned To => BCP Software
2015-02-09 17:09 BCP Software Note Added: 0000338
2015-02-09 17:09 BCP Software Status assigned => resolved
2015-02-09 17:09 BCP Software Fixed in Version => 8.1.3
2015-02-09 17:09 BCP Software Resolution open => fixed
2016-01-20 12:58 BCP Software Category Import/Export => Import and Export
2022-01-10 20:40 BCP Software Note Added: 0002680
2022-01-10 20:40 BCP Software Status resolved => closed