Summary0003967: Download blocked with new cardinality constraint
DescriptionDownloading a model from the server will block when the model contains a cardinality where the minimum is set to a value higher than 1 (and the max is unspecified).
TagsNo tags attached.
CaseTalk Editionunknown

Activities

BCP Software

BCP Software

2023-05-31 13:58

administrator   ~0004854

Initialization of the UC Record set the default of Max to 1. Therefor downloading an UC with only a Min (set to 2), the UC would end up being Min(2) and Max(1). This cannot be, the initialization code is fixed.

Issue History

Date Modified Username Field Change
2023-05-31 13:57 BCP Software New Issue
2023-05-31 13:57 BCP Software Status new => assigned
2023-05-31 13:57 BCP Software Assigned To => BCP Software
2023-05-31 13:58 BCP Software Status assigned => resolved
2023-05-31 13:58 BCP Software Resolution open => fixed
2023-05-31 13:58 BCP Software Fixed in Version => 12.7.4
2023-05-31 13:58 BCP Software Note Added: 0004854