View Issue Details

IDProjectCategoryView StatusLast Update
0003391CaseTalk ModelerTransformation (GLR)public2022-07-05 15:28
ReporterBCP Software Assigned ToBCP Software  
PrioritynormalSeveritymajorReproducibilityhave not tried
Status resolvedResolutionreopened 
Target Version12.4.0Fixed in Version12.5 
Summary0003391: IGG.OTFT not found
DescriptionDuring regular GLR the dialog pops up which states the table IGG.OTFT does not exist.
TagsNo tags attached.
CaseTalk Editionunknown

Activities

BCP Software

BCP Software

2022-03-24 09:43

administrator   ~0004469

image001.png (22,355 bytes)   
image001.png (22,355 bytes)   
BCP Software

BCP Software

2022-07-05 15:27

administrator   ~0004566

Only seems to happen when an IGG is already activated internally, and a manual GLR is run.
BCP Software

BCP Software

2022-07-05 15:28

administrator   ~0004567

The warning does not seem harmful. It is a state handling error, in which a previously connected IGG is closed, and then the data is inserted. Which obviously failed. The close/open is now handled properly.

Issue History

Date Modified Username Field Change
2022-03-24 09:42 BCP Software New Issue
2022-03-24 09:42 BCP Software Status new => assigned
2022-03-24 09:42 BCP Software Assigned To => BCP Software
2022-03-24 09:43 BCP Software Note Added: 0004469
2022-03-24 09:43 BCP Software File Added: image001.png
2022-03-24 10:09 BCP Software Status assigned => resolved
2022-03-24 10:09 BCP Software Resolution open => fixed
2022-03-24 10:09 BCP Software Fixed in Version => 12.4.0
2022-07-05 15:27 BCP Software Status resolved => feedback
2022-07-05 15:27 BCP Software Resolution fixed => reopened
2022-07-05 15:27 BCP Software Note Added: 0004566
2022-07-05 15:28 BCP Software Status feedback => resolved
2022-07-05 15:28 BCP Software Fixed in Version 12.4.0 => 12.5
2022-07-05 15:28 BCP Software Note Added: 0004567