Summary0002557: IGx could not be written
DescriptionWhen saving an IG, the IGx is not created. After opening the IGx by hand, the file seems truncated.
TagsNo tags attached.
CaseTalk Editionunknown

Activities

BCP Software

BCP Software

2020-06-23 13:31

administrator   ~0001676

If text in the model contains a Unit Seperator Character, the IGx cannot be saved. The library used to write XML is tripping over these special characters. How it is entered in CaseTalk is unknown.
BCP Software

BCP Software

2020-06-23 13:32

administrator   ~0001677

Code workaround is implemented to remove unit sperators from xml. It is unknown if this may affect other artifacts.
BCP Software

BCP Software

2022-01-10 20:40

administrator   ~0004115

Closing automatically, stayed too long in resolved state. Feel free to re-open with additional information if you think the issue is not resolved.

Issue History

Date Modified Username Field Change
2020-06-23 13:30 BCP Software New Issue
2020-06-23 13:30 BCP Software Status new => assigned
2020-06-23 13:30 BCP Software Assigned To => BCP Software
2020-06-23 13:31 BCP Software Note Added: 0001676
2020-06-23 13:32 BCP Software Status assigned => resolved
2020-06-23 13:32 BCP Software Resolution open => fixed
2020-06-23 13:32 BCP Software Fixed in Version => 10.2
2020-06-23 13:32 BCP Software Note Added: 0001677
2022-01-10 20:40 BCP Software Note Added: 0004115
2022-01-10 20:40 BCP Software Status resolved => closed